APAR status
Closed as program error.
Error description
Error Message: JVMDUMP000E Dump option unrecognized: -Xdump:system:...file=%uid.MYJVM.%job.T%H%M%S when invoking Dump.systemDumpToFile("%uid.MYJVM.%job.T%H%M%S") . Stack Trace: com.ibm.jvm.InvalidDumpOptionException: Error in dump options. at com.ibm.jvm.Dump.triggerDumpsImpl(Native Method) at com.ibm.jvm.Dump.triggerDump(Dump.java:565) at com.ibm.jvm.Dump.systemDumpToFile(Dump.java:380) at DumpTest.main(DumpTest.java:30) .
Local fix
Use other methods which do not specify a dataset name (Dump.systemDumpToFile(), Dump.SystemDump()) to trigger a system dump, and specify the -Xdump dsn sub-option on the command line, i.e. -Xdump:system:dsn="%uid.MYJVM.%job.T%H%M%S"
Problem summary
The problem is caused when triggering a system dump by specifying the data set name using Dump.systemDumpToFile(String FileNamePattern)
Problem conclusion
The Dump.systemDumpToFile(String fileNamePattern) has been updated to handle the specified fileNamePattern on z/OS . This APAR will be fixed in the following Java Releases: 8 SR5 FP16 (8.0.5.16) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IJ06187
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
270
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-05-03
Closed date
2018-05-10
Last modified date
2018-05-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
R270 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]