Error description

  • Error Message: Segmentation fault(coredump)
    .
    Stack Trace: Large number of calls to findCycle in libj9jit29.so
    at the top of the stack
    .
    

Local fix

  • An Xjit option can be used to prevent compiling the problematic
    method:
    -Xjit:exclude={*methodName*}
    

Problem summary

  • When very large methods get compiled it can cause the recursive
    function findCycle to recurse too many times and trigger a stack
    overflow. The failure will look like a segmentation fault inside
    findCycle.
    

Problem conclusion

  • findCycle was changed from an recursive implementation to an
    iterative one that will not trigger a stack overflow.
    .
    This APAR will be fixed in the following Java Releases:
     8 SR6 FP15 (8.0.6.15)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    Service Refreshes and Fix Packs can be found at:
     https://www.ibm.com/developerworks/java/jdk/
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ26311

  • Reported component name

    JIT

  • Reported component ID

    620700124

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-07-16

  • Closed date

    2020-07-16

  • Last modified date

    2020-07-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    JIT

  • Fixed component ID

    620700124

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
17 July 2020