⇱ IJ27137: AN ASSERT IN PPCBINARYENCODING.CPP MAY TRIGGER WHEN RUNNING WITH TRAPS DISABLED ON POWER


IJ27137: AN ASSERT IN PPCBINARYENCODING.CPP MAY TRIGGER WHEN RUNNING WITH TRAPS DISABLED ON POWER

APAR status

  • Closed as program error.

Error description

  • Error Message: An assert message of the form "Instruction ...
    <OSB>cmplwi<CSB> (generated from node ... <OSB>BNDCHK<CSB>): ...
    is out-of-range for UI field" will be printed and cause the JVM
    to crash.
    .
    Stack Trace: +0x1c8
    +0xd24
    +0x1a8
    +0x670
    +0x4a8
    +0x2b0
    +0x42c
    +0x195c
    +0x107c
    +0x1f84
    +0x84c
    +0xa24
    +0x700
    +0x148
    +0x400
    +0x608
    +0x56c
    +0x22c
    _pthread_body+0x120
    +0x0
    .
    This issue only occurs when either the -Xrs option is specified
    or the noResumableTrapHandler option is specified in the -Xjit
    options on Power.
    

Local fix

  • This crash can be avoided by removing the -Xrs option or
    removing noResumableTrapHandler from the -Xjit options.
    

Problem summary

  • During generation of code for array access bounds checks, the
    range of an immediate was erroneously validated to be a 16-bit
    signed integer when used in an instruction expecting a 16-bit
    unsigned integer.
    

Problem conclusion

  • The JIT has been updated to perform the correct range check when
    generating code for a bound check when traps are disabled.
    .
    This APAR will be fixed in the following Java Releases:
     8 SR6 FP16 (8.0.6.16)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    Service Refreshes and Fix Packs can be found at:
     https://www.ibm.com/developerworks/java/jdk/
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ27137

  • Reported component name

    JIT

  • Reported component ID

    620700124

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-08-19

  • Closed date

    2020-08-25

  • Last modified date

    2020-08-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    JIT

  • Fixed component ID

    620700124

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
26 August 2020