Error description
Error Message: Java process does not end after issuing SIGTERM . Stack Trace: #0 ExtraSymbolsModule::CEEOPCT+0x6a40 #1 ExtraSymbolsModule::pthread_cond_wait+0x1ee #2 libj9thr29.so::omrthread_suspend+0xbe #3 /J8.0_64/lib/s390x/compressedrefs/libj9vm29.so::exitJavaVM+0x5ca #4 ExtraSymbolsModule::JVM_Halt_Impl+0xba #5 /J8.0_64/lib/s390x/compressedrefs/libjvm.so::JVM_Halt+0x138 #6 /J8.0_64/lib/s390x/libjava.so::Java_java_lang_Shutdown_halt0+0x1 4 #7 /J8.0_64/lib/s390x/compressedrefs/libj9vm29.so::FFISYS+0x570 #8 ExtraSymbolsModule::ffi_call+0x8e #9 /J8.0_64/lib/s390x/compressedrefs/libj9vm29.so::bytecodeLoopComp ressed+0x2ae08 #10 /J8.0_64/lib/s390x/compressedrefs/libj9vm29.so::c_cInterpreter+0 x7e #11 /J8.0_64/lib/s390x/compressedrefs/libj9vm29.so::runJavaThread+0x 332 #12 /J8.0_64/lib/s390x/compressedrefs/libj9vm29.so::javaProtectedThr eadProc+0x198 #13 ExtraSymbolsModule::omrsig_protect+0x458 #14 /J8.0_64/lib/s390x/compressedrefs/libj9vm29.so::javaThreadProc+0 x8c #15 libj9thr29.so::thread_wrapper+0x9ba #16 ExtraSymbolsModule::CELQPCMM+0xf80 .
Local fix
Use SIGKILL instead of SIGTERM
Problem summary
Revert the code change that caused this problem
Problem conclusion
The code change that introduced this problem has been reverted . This APAR will be fixed in the following Java Releases: 8 SR6 FP20 (8.0.6.20) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IJ28884
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
270
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-10-23
Closed date
2020-10-23
Last modified date
2020-10-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
R270 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]
Document Information
Modified date:
22 February 2022