APAR status
Closed as program error.
Error description
Error Message: java/lang/NullPointerException received . Stack Trace: java/io/File.<init>(Ljava/lang/String;)V java/lang/Package$1.run()Ljava/lang/Package; java/lang/Package$1.run()Ljava/lang/Object; java/security/AccessController.doPrivileged(Ljava/security/Privi legedAction;)Ljava/lang/Object; java/lang/Package.defineSystemPackage(Ljava/lang/String;Ljava/la ng/String;)Ljava/lang/Package; java/lang/Package.getSystemPackages()<OSB>Ljava/lang/Package; java/lang/VMAccess.getSystemPackages()<OSB>Ljava/lang/Package; com/ibm/oti/vm/BootstrapClassLoader.getPackages()<OSB>Ljava/lang /Package; java/lang/ClassLoader.getPackages()<OSB>Ljava/lang/Package; java/lang/ClassLoader.getPackages()<OSB>Ljava/lang/Package; .
Local fix
Problem summary
Problem is caused when a package ID becomes visible in the classloader hash table before the class defining it has been added to the table.
Problem conclusion
Ensure that both the package ID and the class defining it are in the classloader hash table, or that neither are. . This APAR will be fixed in the following Java Releases: 8 SR7 FP0 (8.0.7.0) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IJ33272
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
270
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-06-16
Closed date
2021-06-25
Last modified date
2021-09-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
R270 PSY
UP