URL: https://www.ibm.com/support/pages/apar/IJ40206

⇱ IJ40206: MISSING HEADER/FOOTER DATA DID NOT CAUSE EXPECTED EXCEPTION


IJ40206: MISSING HEADER/FOOTER DATA DID NOT CAUSE EXPECTED EXCEPTION

APAR status

  • Closed as program error.

Error description

  • Error Message: N/A
    .
    Stack Trace: N/A
    .
    

Local fix

Problem summary

  • IBMJCE did not check for missing data in header/footer.
    

Problem conclusion

  • Added checks to header/footer, and now throws expected
    exception.
    Binary affected - ibmjceprovider.jar
    GIT Issue - #165
    RTC - 146822
    Build - Java 7: build_20220421-634, Java 8: build_20220421-633
    The fix was delivered for: Java 7.0 SR11 FP15 , Java 7.1 SR5
    FP15 , Java 8.0 SR7 FP15
    .
    This APAR will be fixed in the following Releases:
    .
    IBM SDK, Java Technology Edition
     8 SR7 FP15 (8.0.7.15)
     7 R1 SR5 FP15 (7.1.5.15)
     7 SR11 FP15 (7.0.11.15)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    maintenance can be found at:
     https://www.ibm.com/support/pages/java-sdk
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ40206

  • Reported component name

    SECURITY

  • Reported component ID

    620700125

  • Reported release

    270

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-05-23

  • Closed date

    2022-08-04

  • Last modified date

    2022-08-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SECURITY

  • Fixed component ID

    620700125

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"270","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
05 August 2022