APAR status
Closed as program error.
Error description
Error Message: Unhandled exception Type=Illegal instruction . Stack Trace: N/A . Some code for IBM Java 8 is compiled with ARCH(10), which targets 2827-xxx (IBM zEnterprise EC12 (zEC12)) and 2828-xxx (IBM zEnterprise BC12 (zBC12)) models. This may result in an illegal instruction fault when running on earlier models: 2097-xxx (IBM System z10® Enterprise Class) 2098-xxx (IBM System z10 Business Class) 2817-xxx (IBM zEnterprise® 196 (z196)) 2818-xxx (IBM zEnterprise 114 (z114)) Additional code is compiled with ARCH(7), which targets z9, however z9 is not supported since z10 is the minimum supported level.
Local fix
Problem summary
Some code is compiled with ARCH(10) but should be compiled with ARCH(8).
Problem conclusion
The build is updated to compile with ARCH(8). . This APAR will be fixed in the following Releases: . IBM SDK, Java Technology Edition 8 SR8 FP5 (8.0.8.5) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available maintenance can be found at: https://www.ibm.com/support/pages/java-sdk
Temporary fix
Comments
APAR Information
APAR number
IJ45583
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
270
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-02-23
Closed date
2023-02-23
Last modified date
2023-02-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]
Document Information
Modified date:
24 February 2023