VOOZH about

URL: https://www.ibm.com/support/pages/apar/IJ45659

⇱ IJ45659: JAVA JIT: MISSING TYPE CHECKING ALLOWED INVALID OBJECT FIELD ACCESSES


IJ45659: JAVA JIT: MISSING TYPE CHECKING ALLOWED INVALID OBJECT FIELD ACCESSES

APAR status

  • Closed as program error.

Error description

  • Error Message: SIGSEGV in JIT compiled method
    .
    Stack Trace: N/A
    .
    The issue can occur with any OpenJ9 based JVM on any platform.
    The APAR addresses an issue that was not properly covered by the
    previous APAR IJ24023.
    

Local fix

  • The problem can be avoid by disable a JIT optimization using the
    following java command line option:
    -Xjit:disableBlockVersioner
    Using this option will have a minor effect on performance, but
    the cost is very likely to be less then 2% in almost all most
    cases.
    

Problem summary

  • The JIT is doing a compile time instanceOf check in an attempt
    to eliminate the need for a runtime instanceOf check prior to
    executing an optimized block version with bound-checks and
    null-checks removed. This compile time instanceOf was in some
    cases incorrectly passing (eliminating a runtime instanceOf
    check) when it should have failed and generated a runtime
    instanceOf check.
    

Problem conclusion

  • The JIT was modified such that it will generate a runtime
    instanceOf check when one is required.
    https://github.com/eclipse/omr/pull/6906
    .
    This APAR will be fixed in the following Releases:
    .
    IBM SDK, Java Technology Edition
     8 SR8 FP5 (8.0.8.5)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    maintenance can be found at:
     https://www.ibm.com/support/pages/java-sdk
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ45659

  • Reported component name

    JIT

  • Reported component ID

    620700124

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-03-02

  • Closed date

    2023-03-10

  • Last modified date

    2023-03-10

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    JIT

  • Fixed component ID

    620700124

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
11 March 2023