VOOZH about

URL: https://www.ibm.com/support/pages/apar/IJ51598

⇱ IJ51598: JAVA HEALTHCENTER ABORT AT SHUTDOWN ON Z/OS


IJ51598: JAVA HEALTHCENTER ABORT AT SHUTDOWN ON Z/OS

APAR status

  • Closed as program error.

Error description

  • Error Message: Intermittent z/OS crash in libhealthcenter.so
    when stopping Java VM
    .
    Stack Trace: 27 JNIEnv_::GetStaticMethodID(_jclass*,const
    char*,const char*)
     +00000054 *PATHNAM
    
    28
    ibmras::monitoring::plugins::j9::getMXBean(JNIEnv_*,_jclass*
     +00000250 *PATHNAM
    
    29
    ibmras::monitoring::plugins::j9::cpu::CpuPlugin::pullInt()
     +0000080C *PATHNAM
    
    30 ibmras::monitoring::plugins::j9::cpu::pullWrapper()
    
     +00000054 *PATHNAM
    
    31
    ibmras::monitoring::agent::threads::WorkerThread::processLoop
     +000001EE *PATHNAM
    
    32
    ibmras::monitoring::agent::threads::WorkerThread::threadEntry
    .
    

Local fix

Problem summary

  • The problem was caused by ThreadPool::stopAll destructing the
    WorkerThread while it was still running in processLoop. This
    implicitly detached the thread from VM causing aborts while
    shutting down.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IJ51598

  • Reported component name

    J9 COMMON CODE

  • Reported component ID

    620700127

  • Reported release

    270

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-06-22

  • Closed date

    2024-06-25

  • Last modified date

    2024-09-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    J9 COMMON CODE

  • Fixed component ID

    620700127

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date:
18 September 2024