⇱ IV78217: PROBLEM WITH JIT COMPILED CODE WITH AUTO-SIMD WHEN -XJIT:ENABLEG PU IS SPECIFIED


IV78217: PROBLEM WITH JIT COMPILED CODE WITH AUTO-SIMD WHEN -XJIT:ENABLEG PU IS SPECIFIED

APAR status

  • Closed as program error.

Error description

  • Error Message: N/A
    .
    Stack Trace: N/A
    .
    This problem can only occur if auto-SIMD is enabled on either
    the z13 platform or POWER 7 or later platform. In addition, this
    problem can only occur if -Xjit:enableGPU is specified.
    

Local fix

  • Either specify -Xjit:disableAutoSIMD or remove -Xjit:enableGPU
    Note that this may affect performance.
    

Problem summary

  • While performing GPU analysis triggered by the -Xjit:enableGPU
    option, the JIT compiler incorrectly modified a data structure
    that is also used during the autoSIMD transformations. This
    caused incorrect auto-SIMD code to be generated.
    

Problem conclusion

  • The JIT compiler has been updated not to modify auto-SIMD data
    structures during GPU analysis.
    .
    This APAR will be fixed in the following Java Releases:
     8 SR2 (8.0.2.0)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    Service Refreshes and Fix Packs can be found at:
     https://www.ibm.com/developerworks/java/jdk/
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV78217

  • Reported component name

    JIT

  • Reported component ID

    620700124

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-10-21

  • Closed date

    2015-10-21

  • Last modified date

    2015-10-21

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

  • Fixed component name

    JIT

  • Fixed component ID

    620700124

Applicable component levels

  • R130 PSY

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC9HBA","label":"Just In Time (JIT) Compiler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
21 October 2015