⇱ IV86710: INCORRECT VALUE READ FROM JAVA ARRAY ELEMENT


IV86710: INCORRECT VALUE READ FROM JAVA ARRAY ELEMENT

APAR status

  • Closed as program error.

Error description

  • Error Message: N/A
    .
    Stack Trace: N/A
    .
    Reading a Java array element produces an incorrect value,
    especially when the element is overwritten with a constant
    immediately afterward.
    

Local fix

  • This problem can be avoided by passing
    -Xjit:disableSequentialStoreSimplification.
    

Problem summary

  • In some circumstances, an optimization could combine two stores
    into a single store even when doing so would change the result
    of intervening instructions.
    

Problem conclusion

  • The optimization has been modified so that it will not combine
    pairs of stores that have such intervening instructions.
    .
    This APAR will be fixed in the following Java Releases:
     8 SR3 FP10 (8.0.3.10)
     6 R1 SR8 FP30 (6.1.8.30)
     7 SR9 FP50 (7.0.9.50)
     7 R1 SR3 FP50 (7.1.3.50)
     6 SR16 FP30 (6.0.16.30)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    Service Refreshes and Fix Packs can be found at:
     https://www.ibm.com/developerworks/java/jdk/
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV86710

  • Reported component name

    JIT

  • Reported component ID

    620700124

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-07-07

  • Closed date

    2016-07-07

  • Last modified date

    2016-07-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

  • Fixed component name

    JIT

  • Fixed component ID

    620700124

Applicable component levels

  • R130 PSY

       UP

  • R260 PSY

       UP

  • R600 PSY

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC9HBA","label":"Just In Time (JIT) Compiler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
07 July 2016