![]() |
VOOZH | about |
The CData JDBC Driver for PingOne fully implements the JDBC standard and can provide PingOne data connectivity to a wide variety of BI, reporting, and ETL tools and custom applications. In this article, we explain how to set PingOne data as JDBC data source in FineReport and view PingOne data as a table in the Report Designer.
Follow the instruction below to set PingOne data as a FineReport database connection.
Next we will set up the data connection definition in the window.
To connect to PingOne, configure these properties:
is the ID of the PingOne environment in which your Worker application resides. This parameter is used only when the environment is using the default PingOne domain (auth.pingone). It is configured after you have created the custom OAuth application you will use to authenticate to PingOne, as described in Creating a Custom OAuth Application in the Help documentation.
First, find the value for this property:
WorkerAppEnvironmentId='11e96fc7-aa4d-4a60-8196-9acf91424eca'
Now set to the value of the Environment ID field.
is the base URL of the PingOne authorization server for the environment where your application is located. This property is only used when you have set up a custom domain for the environment, as described in the PingOne platform API documentation. See Custom Domains.
PingOne supports both OAuth and OAuthClient authentication. In addition to performing the configuration steps described above, there are two more steps to complete to support OAuth or OAuthCliet authentication:
Set to OAuth.
Get and Refresh the OAuth Access Token
After setting the following, you are ready to connect:
When you connect, the driver opens PingOne's OAuth endpoint in your default browser. Log in and grant permissions to the application. The driver then completes the OAuth process:
The driver refreshes the access token automatically when it expires.
For other OAuth methods, including Web Applications, Headless Machines, or Client Credentials Grant, refer to the Help documentation.
For assistance in constructing the JDBC URL, use the connection string designer built into the PingOne JDBC Driver. Either double-click the JAR file or execute the jar file from the command-line.
java -jar cdata.jdbc.pingone.jar
Fill in the connection properties and copy the connection string to the clipboard.
π Using the built-in connection string designer to generate a JDBC URL (Salesforce is shown.)When you configure the JDBC URL, you may also want to set the Max Rows connection property. This will limit the number of rows returned, which is especially helpful for improving performance when designing reports and visualizations.
A typical JDBC URL is below:
jdbc:pingone:AuthScheme=OAuth;WorkerAppEnvironmentId=eebc33a8-xxxx-4f3a-yyyy-d3e5262fd49e;Region=NA;OAuthClientId=client_id;OAuthClientSecret=client_secret;InitiateOAuth=GETANDREFRESH;
Click Test connection to ensure you have configured the connection properly. With the connection to PingOne set up, you can use it as FineReport data source.
With these simple steps, PingOne can be used as a JDBC data source in FineReport.
Download a free trial of the PingOne Driver to get started:
Download NowLearn more:
π PingOne IconRapidly create and deploy powerful Java applications that integrate with PingOne.