![]() |
VOOZH | about |
You can use the SQL Gateway to configure a TDS (SQL Server) remoting service and set up a linked server for PingOne data. After you have started the service, you can use the UI in SQL Server Management Studio or call stored procedures to create the linked server. You can then work with PingOne data just as you would a linked SQL Server instance.
If you have not already, first specify connection properties in an ODBC DSN (data source name). This is the last step of the driver installation. You can use the Microsoft ODBC Data Source Administrator to create and configure ODBC DSNs.
To connect to PingOne, configure these properties:
is the ID of the PingOne environment in which your Worker application resides. This parameter is used only when the environment is using the default PingOne domain (auth.pingone). It is configured after you have created the custom OAuth application you will use to authenticate to PingOne, as described in Creating a Custom OAuth Application in the Help documentation.
First, find the value for this property:
WorkerAppEnvironmentId='11e96fc7-aa4d-4a60-8196-9acf91424eca'
Now set to the value of the Environment ID field.
is the base URL of the PingOne authorization server for the environment where your application is located. This property is only used when you have set up a custom domain for the environment, as described in the PingOne platform API documentation. See Custom Domains.
PingOne supports both OAuth and OAuthClient authentication. In addition to performing the configuration steps described above, there are two more steps to complete to support OAuth or OAuthCliet authentication:
Set to OAuth.
Get and Refresh the OAuth Access Token
After setting the following, you are ready to connect:
When you connect, the driver opens PingOne's OAuth endpoint in your default browser. Log in and grant permissions to the application. The driver then completes the OAuth process:
The driver refreshes the access token automatically when it expires.
For other OAuth methods, including Web Applications, Headless Machines, or Client Credentials Grant, refer to the Help documentation.
See the SQL Gateway Overview for a guide to configure a TDS remoting service in the SQL Gateway UI. The TDS remoting service is a daemon process that listens for TDS requests from clients.
After you have configured and started the daemon, create the linked server and connect. You can use the UI in SQL Server Management Studio or call stored procedures.
Follow the steps below to create a linked server from the Object Explorer.
Data Source: Enter the host and port the TDS remoting service is running on, separated by a comma.
Note that a value of "localhost" in this input refers to the machine where SQL Server is running so be careful when creating a linked server in Management Studio when not running on the same machine as SQL Server.
In addition to using the SQL Server Management Studio UI to create a linked server, you can use stored procedures. The following inputs are required:
datasrc: The host and port the service is running on, separated by a comma.
Note that a value of "localhost" in the datasrc input refers to the machine where SQL Server is running, so be careful when creating a linked server in Management Studio when not running on the same machine as SQL Server.
Call sp_addlinkedserver to create the linked server:
EXEC sp_addlinkedserver @server='PingOne', @provider='MSOLEDBSQL', @datasrc='< MachineIPAddress >,1434', @catalog='CData PingOne Sys', @srvproduct=''; GO
Call the sp_addlinkedsrvlogin stored procedure to allow SQL Server users to connect with the credentials of an authorized user of the service. Note that the credentials you use to connect to the service must specify a user you configured on the Users tab of the SQL Gateway.
EXEC sp_addlinkedsrvlogin @rmtsrvname='PingOne', @rmtuser='admin', @rmtpassword='test', @useself='FALSE', @locallogin=NULL; GO
SQL Server Management Studio uses the SQL Server Client OLE DB provider, which requires the ODBC driver to be used inprocess. You must enable the "Allow inprocess" option for the SQL Server Native Client Provider in Management Studio to query the linked server from SQL Server Management Studio. To do this, open the properties for the provider you are using under Server Objects -> Linked Servers -> Providers. Check the "Allow inprocess" option and save the changes.
You can now execute queries to the PingOne linked server from any tool that can connect to SQL Server. Set the table name accordingly:
SELECT * FROM [linked server name].[CData PingOne Sys].[PingOne].[[CData].[Administrators].Users]👁 The result of a query in SQL Server Management Studio. (Salesforce is shown.)
Download a free trial of the PingOne ODBC Driver to get started:
Download NowLearn more:
👁 PingOne IconThe PingOne ODBC Driver is a powerful tool that allows you to connect with live data from PingOne, directly from any applications that support ODBC connectivity.
Access PingOne data like you would a database - read, write, and update PingOne 0, etc. through a standard ODBC Driver interface.